Go Bust MIC

Go MICBUSTERS

How to Sample for MIC on Brazilian Pre-Salt FPSOs
Sampling · produced water · filters · deposits · biofilm

How to Sample for MIC on Brazilian Pre-Salt FPSOs

For MIC investigations, the quality and representativeness of the sample usually matter more than the analytical sensitivity printed on a test-kit specification sheet.

Quick answer: combine repeatable water trends with interface samples

Use water for reproducible process surveillance and collect filters, deposits, corrosion products or swabs when the question concerns a surface-associated process. Document sample area, mass or volume and preserve the sample for the intended method.

A sensitive qPCR assay cannot recover information that was never captured by the sample.

MIC is commonly associated with a metal–biofilm–deposit interface, yet routine offshore programmes often collect only the easiest flowing water. Water is valuable for trends, but the organisms released into the fluid do not necessarily occur in the same abundance or condition as organisms attached to steel, embedded in corrosion products or retained in filters.

A sample hierarchy for different FPSO questions

MatrixBest useMinimum documentationKey limitation
Flowing waterRepeatable surveillance and paired treatment-train comparisonsPoint, time, temperature, flow state, flush, volume, chemistry and treatment timingMay poorly represent attached biofilm
First flush or low-point waterIntermittent lines, drains and local accumulationStagnation duration and whether sample is first flush or post-flushNot comparable with routine fully flushed water
Filter or membraneConcentrating biomass from a known water volume; examining retained solidsFiltered volume, pore size, pressure/flow and filter handlingFilter bias and extraction inhibition must be checked
Deposit, sludge or corrosion productUnder-deposit and interface investigationExact location, wet mass, appearance, depth/layer and exposure conditionsHeterogeneous; subsampling can dominate variability
Surface swabDefined accessible area during inspection or maintenanceArea in cm², surface condition, swab pattern, blank and bufferRecovery depends on technique and surface roughness
Coupon or removable specimenLinking biofilm, corrosion and exposure historyArea, metallurgy, exposure time, orientation and cleaning sequenceCoupon may not reproduce the most vulnerable geometry

A defensible field procedure

  1. Define the analytical split before opening the point. Culture, ATP, DNA-qPCR, RNA analysis, chemistry and mineralogy require different containers, preservatives and timing.
  2. Record the operating state. Note well routing, flow, temperature, pressure, chemical dosing, elapsed time after biocide and recent shutdown or restart.
  3. Control the sampling point. For a routine water trend, apply a consistent flush rule. For a first-flush investigation, capture and label it explicitly.
  4. Use sterile, compatible tools. Change tools between locations. Include a field blank for swabs, filters and complex deposit campaigns.
  5. Homogenise only when scientifically appropriate. A composite deposit can answer an average-composition question but may erase the difference between the metal interface and outer layer.
  6. Preserve immediately. Match preservation to the target. Do not preserve a culture aliquot with a DNA lysis or fixation reagent.
  7. Keep the chain of context. Sample IDs must link to location, photograph, matrix, basis, time and requested analyses.

For accessible surfaces, use a defined template and a reproducible swabbing pattern. The MICBUSTERS swab sampling guide explains area definition, blanks and handling. When samples must travel, review preservation for oilfield qPCR and the effect of holding time and transport.

qPCR quality controls for offshore matrices

Produced water, crude residues, corrosion inhibitors, sulfides, iron minerals and fine solids can inhibit DNA extraction or amplification. A negative reaction without an inhibition control is therefore incomplete evidence. A field workflow should include:

  • a field blank for collection contamination;
  • an extraction blank for batch contamination;
  • a positive amplification control;
  • an internal amplification or inhibition control;
  • replicate extraction or analysis where heterogeneity is expected;
  • a recorded reporting basis: mL, filtered volume, gram, filter, coupon or cm².
Important: a non-detect can mean that the target is below the method’s detection capability in that analysed portion. It does not mean “zero microorganisms,” and it does not exclude a different organism, gene or unsampled biofilm.

A compact campaign design

Routine quarterly or monthly trend

Use fixed water points, defined flushing, constant volume, the same assays and aligned chemistry. Add filters when biomass is expected to be low or solids capture is operationally relevant.

Inspection opportunity

Prioritise defined-area swabs, separate interface and outer deposits, photograph morphology and coordinate samples with UT, pit mapping or materials analysis.

Biocide event

Collect baseline and time-resolved downstream samples at realistic residence times. Neutralise aliquots intended for culture or ATP when validated.

Unexpected result

Repeat the extraction or dilution for inhibition, confirm metadata, examine the paired filter or deposit and avoid changing treatment on a single unexplained number.

AMPP TM21465-2024 provides a framework for sample handling and processing when molecular microbiological methods are used. It should be applied together with the asset’s safety, hazardous-area, sampling and integrity procedures.

Contact Oil Tech Brazil

Share the process flow, accessible sample points and intended decisions. Oil Tech Brazil and MICBUSTERS can help define matrices, controls, field qPCR targets and a reporting basis that supports useful comparisons.

Use the Brazil contact form to discuss your asset, a demonstration, a pilot programme or implementation of on-site qPCR. The local Oil Tech Brazil team will follow up.

Frequently asked questions

Is water enough for an FPSO MIC investigation?

Usually not when corrosion at a surface is the concern. Water is useful for trending, but deposits, corrosion products, swabs, filters or coupons provide more direct interface evidence.

Should a sample point be flushed before collection?

For routine trends, use a defined and repeatable flush procedure. For a stagnation or first-flush question, do not erase that signal; collect and label it separately.

How should qPCR results from deposits be reported?

Report the sample basis, such as copies per gram of wet or dry material, and document homogenisation, extraction mass and heterogeneity. Do not compare directly with copies per millilitre.

Why is an inhibition control essential?

Oil, salts, metals, treatment chemicals and fine solids can suppress extraction or amplification. An inhibition control helps distinguish a true non-detect from analytical suppression.

Can the same aliquot be used for culture and DNA preservation?

Not after adding a preservation or lysis reagent that prevents growth. Plan separate aliquots and handling routes before sampling.

Related MICBUSTERS resources

References and further reading

  1. AMPP TM21465-2024: Molecular Microbiological Methods—Sample Handling and Laboratory Processing.
  2. AMPP TM0212: Detection, Testing, and Evaluation of MIC on Internal Pipeline Surfaces.
  3. Eckert & Skovhus (2018), Molecular microbiological methods in oil and gas and links to MIC.
  4. Knisz et al. (2023), Microbiologically influenced corrosion—more than just microorganisms.
  5. Domingues et al. (2025), Sulfide production and microbial dynamics in a Brazilian offshore water-reinjection system.
  6. Bustin et al. (2009), The MIQE guidelines for publication of quantitative real-time PCR experiments.
  7. Oil Tech Brazil: MIC monitoring in pipelines and oil & gas systems.

MICBUSTERS disclaimer: This article is intended for informational and educational purposes and does not replace project- or asset-specific scientific or engineering assessment. MICBUSTERS has a commercial interest in MIC monitoring solutions, including an on-site qPCR kit.

Results and recommendations depend on sampling quality, analytical method, asset conditions and operational variability. Detection of a DNA target does not, by itself, prove metabolic activity, MIC causation or a corrosion rate. Mitigation decisions remain the responsibility of the asset owner and its appointed advisers.

Privacy Overview
Logo

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful. For more information visit our Privacy Policy page.

Necessary Cookies

Necessary Cookie required the page to work properly and save your preferences for cookie settings.

3rd Party Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.